| All Products - China & Asia - Auto Regular Heating Cables - Temperature-controlled heating cable
|
|
|
| |
Mid-length type, mid-length strengthening type:
Low, mid/high-temperature series mid-length type heating cable is suitable for long pipeline, vessel and tank to prevent frostbite, keep warm, reduce condensation and trace heat. It is suitable for common area, dangerous area and corrosive area.
Cable structure:
1. Silvered aluminum alloy copper conductor
2. Conductive plastic layer
3. Fluorplastic insulation layer
4. Tinned copper wire insulation layer
5. Fluorplastic restrictive coating
Technical index
1. Standard color: low temperature: black; mid temperature: brown; high temperature: red
2. Temperature range: low temperature: 65+/-5oC; mid temperature: 105+/-5oC; high temperature: 135+/-5oC
3. Voltage grade: 24V, 36V, 110V, 220V, 380V
4. Insulation resistance: If cable length is 100m and environment temperature is 75oC, test with 2,500VDC meter for1min and then insulation resistance is 3000Mohm at least.
Advantage: 1. Heating pipe is even in temperature. It will not be over-heat but safe and reliable. 2. Save electric energy. 3. Temperature increases rapidly during intermittent operation. 4. Cost of installation and operation is low. 5. It is easy to install and maintain. 6. It is convenient for automatic management. 7. It does not pollute environment.
Installation Works for Self-Regulating Heating Cables
Preparing Work:
(1). Test the electronic circuit integrated and insulation capability of all cable tracing.
(2). Exterior inspections both Electronic equipment and control, could not use the transmutative, Chapped, spare part are not completed and could not repair
(3). Check up the pipe serial number according to heating cable chart. Then install as been confirmed correct.
(4). It can not be installed without Products tagged, blurred or unable to identify,
(5). The Work of Heating pipes must be completed and tested by Hydraulic test (Hermetic experiment).
The installation Plan .
|