| All Products - China & Asia - Control Cables - XLPE insulation control cables
|
|
|
| |
Product information:
XLPE insulated control cable
Executive standard
GB9330-1988
Use:
XLPE insulated control cable is suitable for DC and AC 50HZ 600/1000V power plants, transmission stations, factories, petrol chemical companies as the connection cable among automatic control instruments for transmitting electric power and signal to ensure safe running of the electric system.
Technical features:
1.Finished cable is subjected to 3500V AC voltage for 5min without breakthrough.
2.Insulation resistance is not less than 0.385MOHM.Km at 90oC.
3.It is better than PE insulated control cable in terms of heatproof, freezing-proof, chemical
resistance and electric performance, insulation resistance and life time.
Working condition:
1.Permitted long-term working temperature of conductor is 90oC.
2.Laying temperature should be lower than 0oC. Recommended bending radius:
Not less than 6 times of the outer diameter without armoring layer; Not less than 12 times of the outer diameter with armoring or screening layer; Not less than 6 times of the outer diameter with screening layer
Model and name
|
Model |
Name |
Application |
|
KYJV |
XLPE insulated PVC sheathed control cable |
Used as connection cables for electric instrument under 0.6/1kV |
|
KYJV22 |
XLPE insulated steel-tape armoured PVC sheathed control cable |
|
KYJVP |
XLPE insulated copper-wire screening PVC sheathed control cable |
Used in the place where screening is required |
|
KYJVP2 |
XLPE insulated copper-tape screening PVC sheathed control cable |
Used in the place where screening is required. |
|
KYJVP2-22 |
XLPE insulated PVC sheathed copper-tape screening steel-tape armoured control cable |
|
ZR-KYJV |
XLPE insulated PVC sheathed control cable |
Used in the place where flame retardancy is required. |
|
ZR-KYJV22 |
XLPE insulated steel-tape armoured PVC sheathed flame-retardant control cable |
|
ZR-KYJVP |
XLPE insulated copper-tape screening PVC sheathed flame retardant control cable |
|
ZR-KYJVP2 |
XLPE insulated copper-tape screening PVC flame-retardant control cable |
|
ZR-KYJVP2-22 |
XLPE insulated PVC sheathed copper-tape screening steel-tape armoured flame-retardant control cable |
|
NH-KYJV |
XLPE insulated PVC sheathed fireproof control cable |
Used in the place where fire resistance is required. |
|
NH-KYJV22 |
XLPE insulated PVC sheathed steel-tape armoured fireproof control cable |
|
NH-KYJVP2 |
XLPE insulated PVC sheathed copper-tape screening fireproof control cable |
|
NH-KYJVP2-22 |
XLPE insulated PVC sheathed copper-tape screening steel-tape armoured fireproof control cable |
Specification
|
Nominal section mm2 |
KYJV |
KYJVP |
KYJVP2 |
KYJV22,KYJVP2-22 |
Note: Flame-retardant or fire-retardant cable is the same as above.
Technical requirement DC resistance of finished cable at 20oC
|
Nominal section mm2 |
0.75 |
1.0 |
1.5 |
2.5 |
4 |
6 |
10 |
|
DC resistance at 20oC OHM/Km |
24.5 |
18.1 |
12.1 |
7.41 |
4.61 |
3.08 |
1.83 |
Structural drawing

|